Pressure Transducers & Transmitters
V-Flow Solutions Ltd offer an extensive range of Ashcroft Pressure Transducers with a polysilicon thin film element. Each are available with an internal or flush diaphragm, all process wetted parts stainless steel. Pressures for Ashcroft Transducers range from -1…0 up to 0…1400 bar with accuracy of 0.5%. Each Ashcroft Transducer is manufactured to a high quality industry recognised standard. Our wide range of Ashcroft Pressure Transducers includes the following: |
- Compact Size
- Output 4-20 mA
- Process connection G¼ B or ¼ NPT
Model KM11
- Ranges up to 2500 bar
- Accuracy 1% or 0.5%
- Optional intrinsically safe according to ATEX EEx ia IIC T4
- Various process and electrical connections
- Standard execution
- Output 0 / 4-20 mA, 0-5 / 10 VDC
- Optional intrinsically safe according to ATEX EEx ib IIC T5/T6
- Flush diaphragm
- Output 0 / 4-20 mA, 0-5 / 10 VDC
- Optional intrinsically safe according to ATEX EEx ia IIC T4
- Process connection G¼ B or ¼ NPT
- High temperature execution for process temp. to 200oC
- Compact size
- Accuracy 1%
- Output 0 / 4-20 mA, 0-5 / 10 VDC
- Ranges up to 1400 bar
- Accuracy 1% Total Error Brand or 0.25% BFSL
- Output signal 4-20 mA, ratiometric and voltage
- Various process and electrical connections
MODEL G2 | MODEL T2 |
Pressure Transducers Model A2, A2X and A4
- Ranges 0…350 mbar up to 0…600 bar gauge or 0…1 up to 0…500 bar absolute
- Accuracy 1%, 0.5%, 0.25%
- Optional temperature compensated -40…120oC
- Output 4-20 mA or voltage
- Threaded process connection with internal diaphragm or flush diaphragm with Tri-Clamp sanitary connection
- UL, FM and CSA approved
MODEL A2 | MODEL A2X | MODEL A4 |
Capacitance differential pressure transducer, transmitters for dry gases
The Ashcroft Model XLdp ranges of transducer/transmitters have a micro machined differential capacitance silicon sensor with ranges from 0.25 mbar up to 500 mbar differential pressure. The Model XLdp has an excellent longterm stability and overpressure capability with output 4-20 mA or various voltage signals. The numerous types of Ashcroft Model XLdp includes the following:
- Small OEM version
- Ranges up to 125 mbar
- Accuracy 1%
- Industrial execution with stainless steel enclosure
- Ranges up to 500 mbar
- Static pressure 7 bar
- Accuracy 0.5% or 0.25%
- General application
- Ranges up to 125 mbar
- Accuracy 0.5% or 0.25%
- DIN rail mounting
- Building energy management and comfort control
- Ranges from 0…25 Pa up to 0…600 mbar
- Accuracy 0.8% or 0.4%
- Output 4-20 mA
- DIN rail mounting
- Ranges up to 125 mbar
- Accuracy 1%, 0.5% or 0.25%
- SpoolCalTM process valve
- Diagnostic LED and test points
- 2:1 turn down
Rangeable pressure and wet/wet dp-transmitter with local indication
- Thin film sensor element
- Ranges from -1…1 up to 0…500 bar
- Accuracy 0.25%
- Output 4-20 mA
- Loop check function
- Capacitive sensor
- Ranges from 10 up to 1000 mbar dp
- Static pressure 20 bar
- Accuracy 0.5%
- Output 4-20 mA
- Combined 3-in-1 digital pressure gauge, switch and transducer
- Ranges to 600 bar
- Accuracy 1%
- Output 4-20mA